Meco 801-Auto Digital Multimeter

Product Code: Meco801-AutoDigitalMultimeter362

Quantity :

  • Availability : in stock
  • 1500
  • 1999
  • You saving : 499
Colour :

About this item

DC Voltage : 400mV/4/40/400/1000V DC
AC Voltage : 4/40/400/750V AC
DC Current : 400/4000uA/40/400mA/4/20A DC
AC Current : 400/4000uA/40/400mA/4/20A AC
Resistance : 400Ω/4/40/400KΩ/4/40MΩ
Capacitance : 40/400nF/4/40/100uF
Frequency : 0.5Hz ~ 10MHz(9999 Counts)
Duty Cycle : 0.1% ~ 99.9%
Temperature : - 20ºC ~ 1300ºC / - 4ºF ~ 1999ºF
Display3999 counts  liquid crystal display (LCD) 15.0mm height, max. reading 3999, automatic decimal points selection and
annunciators of mV, V, µA, mA, A, V, KV, MV, AC, DC, AUTO , KHz, MHz, nF, µF, H, OC, %
Range SelectionAuto & Manual for DC, AC Voltage, Resistance, µA, mA & ‘A’ measurement Auto only for Frequency, capacitance, Temperature measurement
PolarityAutomatic, (-) negative polarity indication
Zero adjustmentAutomatic for all ranges except capacitance (manual zero)
Over range indication · ‘ OL ’ is displayed except in 1000V DC,
750V AC and 20A AC/DC range
Low batterymark turns on
Sample rate3 measurement per second
Operating conditions0°C to +50°C, 0 - 75% RH (Noncondensing)
Storage conditions-20°C to +60°C, 0 - 80% RH with battery removed
AccuracyAccuracy specification at 27° ± 5°C and less than 75% RH
Power SupplyTwo Standard 1.5V battery Eveready type 1015 or equivalent
Battery life (typical)200 hours
Dimensions161 x 86 x 33 mm
Weight275 gms (approx.)
AccessoriesTest leads (pair), carring case, battery, Instructional manual  & K Type Thermocouple

 

Electrical Specification

Accuracies are ± (% reading + number of digits) at 27° ± 5°C and humidity of less than 75% RH

DC VOLTAGE (Auto & Manual Ranging)

Range

400mV, 4V, 40V, 400V, 1000V

Accuracy

± (0.5% rdg + 4 dgt) on 400mV & 4V

± (0.7% rdg + 4 dgt) on 40V & 400V

± (1.0% rdg + 4 dgt) on 1000V

Resolution

0.1mV to1V

Input Impedance

10MΩ on all ranges

Overload Protection : 500V DC / 350V AC for 15 sec. on 400mV

Overload Protection

Range, 1200V DC / 800V AC on all ranges

AC VOLTAGE (Auto & Manual Ranging) 50-500Hz

Range

4V, 40V, 400V, 750V

Accuracy

± (1.0% rdg + 5 dgt) on all ranges except

± (1.5% rdg + 8 dgt) on 750V

Resolution

1mV to 1V

Input Impedance

10MΩ on all ranges

Overload Protection

1200V DC / 800V AC on all ranges

DC CURRENT (Auto & Manual Ranging)

Range

400µA, 4000µA, 40mA, 400mA , 4A, 20A

Accuracy

± (1.5% rdg + 4 dgt)

Resolution

0.1µA to 0.01A

Burden Voltage

< 0.7V on 200mA

< 0.25V on 20A

Overload Protection

 

0.8A / 250V fuse on 400mA

20A / 600V fuse on 20A

AC CURRENT (Auto & Manual Ranging) 50-500Hz

Range

400µA, 4000µA, 40mA, 400mA, 4A, 20A

Accuracy

± (2.2% rdg + 4 dgt)

Resolution

0.1µA to 0.01A

Burden Voltage

< 0.7V on 400mA

< 0.25V on 20A

Overload Protection

0.8A / 250V fuse on 400mA

20A / 600V fuse on 20A

RESISTANCE (Auto & Manual Ranging)

Range

400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ,

Accuracy

± (0.7% rdg + 4 dgt) on all ranges except

± (1.2% rdg + 4 dgt) on 4MΩ,

± (2.5% rdg + 4 dgt) on 40MΩ

Resolution

0.1Ω to 0.01MΩ

Test Current

Approx 0.7mA on 400Ω, 0.1mA on 4KΩ,

30µA on 40KΩ, 4µA on 400KΩ

Overload Protection

500V DC/AC

FREQUENCY (Auto Ranging)

Range

9.999Hz, 99.99Hz, 999.9Hz, 9.999kHz,

99.99kHz, 999.9kHz, 9.999MHz

Accuracy

± (0.5% rdg + 2 dgt)

% DUTY CYCLE (Auto Ranging)

Range

0.1% to 99.9%

Accuracy

± (0.5% rdg + 2 dgt)

Resolution

0.10%

CAPACITANCE (Auto Ranging)

Range

40nF, 400nF, 4µF, 40µF, 100µF

Accuracy

± (5.0% rdg + 10 dgt)

Resolution

1pF  to 0.01nF

TEMPERATURE

Range

-20OC ~ 1300OC

Accuracy

± (2.0% rdg + 4 dgt)

Resolution

1 Degree C

Sensor

K Type Thermocouple

Related Products

© 2016 Sparkinstrument.com . All rights reserved | Design by ITS Gwalior.